- Single sensor and dual sensor (2 temperature and 2 door-open sensors) available.
- Paper-thin cable maintains gasket seal integrity.
- Easily replaceable NIST-traceable tip for simple calibration.
- Industrial door-open sensor helps troubleshoot temperature alerts, as well as tracking each time the door is opened. Sensor device node takes a reading and transmits every time the door is opened and closed.
- Time that door is left open is reported - and alarms can be set on excessive door-open time.
- Optional wall transformer powers the sensor and also alerts power outages. On-board battery backup assures sensor node operation during power outages.
- Fast, simple installation with cold-proof foil stickers and adhesive-backed hook-and-loop.
- Thermal mass bottle prevents false alarms from defrost cycles or when the door is opened.
- Know for sure the sensor is connected & working with LED indicator light.
-
This Leap Sensor comes with a fast-to-install split-core AC amp clamp to sense the AC electrical current going to equipment. Amp clamps are a powerful industrial tool to monitor power usage and to monitor equipment for conditions that predict impending failures. A change in AC current to industrial equipment can be an early indication to plan downtime to prevent failures during production. A wide range of amp clamps can be integrated with the Leap system. Contact us with your specific needs.Price for 0-50A AC RMS current transformer. Contact us for pricing on other current transformer options.Contact Us
Prices, Quotes, Questions...
Need a price or a quote? Have questions? Want to talk to an expert? Need a custom solution?Contact Us -
Vibration sensor can measure G-forces. Vibration sensor takes a simple yet highly effective approach in monitoring maximum and average g-force trends of +/-16G and can sample at up to 5 KHz on all 3 axes. The accelerometer has optional advanced on-board edge computing FFT capabilities. Customized options include vibration, tilt, and shock events. Up to 8 vibration modules can be attached to one transceiver node. The vibration module also includes a temperature sensor.
Video Demonstration and Tutorial
Transceiver Node Configuration
Vibration+Temperature Modules: The number of vibration/temperature modules (1-8) connected to the Vibration Transceiver Node can be selected on the vibration module page. Build your quote here: -
This unique Leap wireless sensor attaches to the top of a silicon wafer for fabrication process monitoring. It is less than 5mm thick, so it fits in wafer processing ovens and other critical fab equipment. The sensor has 9 ultra-small, high-accuracy RTD sensors that are adhered to the surface of the wafer, giving you better accuracy than a wireless thermocouple wafer sensor (tc wafer sensor).
- 3-wire RTD connection supports long cables while maintaining temperature accuracy during rapid heating.
- The entire sensor is rated to operate up to at least 125ºC (257ºF).
- Readings as fast as every 10 seconds for each of the 9 sensors.
- Field replaceable batteries.
- Data logging capability when the transceiver node is not linked to a gateway.
-
This highly versatile industrial sensor supports 9 miniature, low-mass precision RTD temperature sensors connected to a high-temperature transceiver node in an industrial enclosure.
- 3-wire RTD connection supports long cables while also maintaining high temperature accuracy.
- The entire sensor is rated to operate up to at least 125C (257F).
- Readings as fast as every 3 seconds for each of the 9 sensors.
- Data logging capability when the transceiver node is not linked to a gateway.
-
This unique Leap wireless sensor is less than 5mm thick and supports 9 ultra-small, high-accuracy RTD sensors.
- 3-wire RTD connection supports long cables while also maintaining high temperature accuracy.
- The entire sensor is rated to operate up to at least 125C (257F).
- Readings as fast as every 3 seconds for each of the 9 sensors.
- Data logging capability when the transceiver node is not linked to a gateway.
- Silicon wafer processing
- Scientific experiments
- Paint and coatings curing
- Temperature profiling over a surface
-
This Leap wireless sensor has a standard mini thermocouple connectors that can connect to any thermocouple. (Standard products comes with K-Type thermocouples.) Other thermocouple types are also available - type-B, type-S, etc. Because thermocouples can be used over a wide temperature range and thermocouples come in a huge range of probe types, this sensor addresses many industrial applications - and is one of our most popular industrial wireless sensors.Part of the breakthrough Leap Sensors® system. Build your quote here:
-
This Leap wireless sensor has two standard mini thermocouple connectors that can connect to any K-type thermocouple. Because thermocouples can be used over a wide temperature range and thermocouples come in a huge range of probe types, this sensor addresses many harsh industrial applications.Part of the breakthrough Leap Sensors® system. Build your quote here:
-
Very easy and intuitive to use, Cloud-based SensorManager.com lets you manage your wireless network and set alerts. Designed to work with the Leap Sensors® system. Learn more about Leap SensorsContact us for software options and pricing.Contact Us
Prices, Quotes, Questions...
Need a price or a quote? Have questions? Want to talk to an expert? Need a custom solution?Contact Us